[1560]
Jankowski, M. Jan, R. Olsen, C. Nielsen, Y. Thomassen, and P. Molander,
"The applicability of proton transfer reaction-mass spectrometry (PTR-{MS}) for determination of isocyanic acid ({ICA}) in work room atmospheres",
Environmental Science: Processes & Impacts, 2014.
Link:
http://dx.doi.org/10.1039/C4EM00363B
<p>A method is presented for the real-time quantitative determination of isocyanic acid (ICA) in air using proton transfer reaction-mass spectrometry (PTR-MS). Quantum mechanical calculations were performed to establish the ion-polar molecule reaction rate of ICA and other isocyanates. The PTR-MS was calibrated against different ICA air concentrations and humidity conditions using Fourier transform-infrared spectroscopy (FT-IR) as quantitative reference. Based on these experiments a simple humidity dependant model was derived for correction of the PTR-MS response for ICA. The corrected PTR-MS data was linearly correlated (R2 > 0.99) with the data acquired by FT-IR. The PTR-MS instrumental limit of detection (LOD) for ICA was 2.3 ppb. Humid atmospheres resulted in LODs of 3.4 and 7.8 ppb, at an absolute humidity (AH) of 4.0 and 15.5 g m-3, respectively. Furthermore, off-line sampling using denuder and impinger samplers using di-n-butylamine (DBA) as derivatization reagent was compared with PTR-MS measurements in a dynamically generated standard ICA atmosphere. Denuder (n = 4) and impinger (n = 4) sampling subsequent to liquid chromatography mass spectrometry (LC-MS) determination compared to corrected PTR-MS data resulted in recoveries of 79.6 (8.1 % RSD) and 99.9 (9.3 % RSD) %, respectively. Measurements of ICA from thermally decomposed cured 1,6-hexamethylene diisocyanate (HDI)-paint was performed used PTR-MS and denuder (n = 3) sampling. The relation between the average ICA responses using denuders (34.4 ppb) and PTR-MS (42.6 ppb) was 80.6 %, which coincided well with the relative recovery obtained from the controlled laboratory experiments using dynamically generated ICA atmospheres (79.6 %). The variability in ICA air concentration during the welding process (170 % RSDPTR-MS) illustrated the need for real-time measurements.</p>
[1636]
Jankowski, M. Jan, R. Olsen, C. Jørgen Nielsen, Y. Thomassen, and P. Molander,
"The applicability of proton transfer reaction-mass spectrometry (PTR-MS) for determination of isocyanic acid (ICA) in work room atmospheres.",
Environ Sci Process Impacts, vol. 16, pp. 2423–2431, 2014.
Link:
http://dx.doi.org/10.1039/c4em00363b
<p>A method is presented for the real-time quantitative determination of isocyanic acid (ICA) in air using proton transfer reaction-mass spectrometry (PTR-MS). Quantum mechanical calculations were performed to establish the ion-polar molecule reaction rate of ICA and other isocyanates. The PTR-MS was calibrated against different ICA air concentrations and humidity conditions using Fourier transform-infrared spectroscopy (FT-IR) as quantitative reference. Based on these experiments a simple humidity dependant model was derived for correction of the PTR-MS response for ICA. The corrected PTR-MS data was linearly correlated (R(2) > 0.99) with the data acquired by FT-IR. The PTR-MS instrumental limit of detection (LOD) for ICA was 2.3 ppb. Humid atmospheres resulted in LODs of 3.4 and 7.8 ppb, at an absolute humidity (AH) of 4.0 and 15.5 g m(-3), respectively. Furthermore, off-line sampling using denuder and impinger samplers using di-n-butylamine (DBA) as derivatization reagent was compared with PTR-MS measurements in a dynamically generated standard ICA atmosphere. Denuder (n = 4) and impinger (n = 4) sampling subsequent to liquid chromatography mass spectrometry (LC-MS) determination compared to corrected PTR-MS data resulted in recoveries of 79.6 (8.1% RSD) and 99.9 (9.3% RSD) %, respectively. Measurements of ICA from thermally decomposed cured 1,6-hexamethylene diisocyanate (HDI)-paint was performed using PTR-MS and denuder (n = 3) sampling. The relation between the average ICA responses using denuders (34.4 ppb) and PTR-MS (42.6 ppb) was 80.6%, which coincided well with the relative recovery obtained from the controlled laboratory experiments using dynamically generated ICA atmospheres (79.6%). The variability in ICA air concentration during the welding process (170% RSDPTR-MS) illustrated the need for real-time measurements.</p>