Callback Service

Undefined

The world's leading PTR-MS company

Providing ultra-sensitive solutions for real-time trace gas analysis since 1998

Navigation

You are here

Scientific Articles - PTR-MS Bibliography

Welcome to the new IONICON scientific articles database!

Publications

Found 2 results
Title [ Year(Asc)]
Filters: Author is Haidacher, Stefan  [Clear All Filters]
2013
[Hartungen2013] Hartungen, E., S. Juerschik, A. Jordan, A. Edtbauer, S. Feil, G. Hanel, H. Seehauser, S. Haidacher, R. Schottkowsky, L. Märk, et al., "Proton transfer reaction-mass spectrometry: fundamentals, recent advances and applications", The European Physical Journal Applied Physics, vol. 61, no. 02: Cambridge Univ Press, pp. 24303, 2013.
Link: http://journals.cambridge.org/production/action/cjoGetFulltext?fulltextid=8836242
Abstract
Proton transfer reaction-mass spectrometry (PTR-MS) offers many advantages for trace gas analysis, including no sample preparation, real-time analysis, high selectivity and sensitivity, ultra-low detection limits and very short response times. These characteristic features have made it an ideal tool for many applications in science, technology and society. Here we will discuss recent developments, in particular advances concerning sensitivity, selectivity and general applicability.
2010
[Jordan2010] Jordan, A., P. Sulzer, S. Juerschik, S. Jaksch, G. Hanel, E. Hartungen, H. Seehauser, L. Maerk, S. Haidacher, R. Schottkowsky, et al., "Extremely high mass resolution and sensitivity-comparison of two novel proton transfer reaction time-of-flight mass spectrometers (PTR-TOFMS)", Verhandlungen der Deutschen Physikalischen Gesellschaft, vol. -, no. Hanver 2010 issue, pp. -, 2010.
Link: https://www.etde.org/etdeweb/details_open.jsp?osti_id=21329230
Abstract
Since many years PTR-MS is a well established technique in trace gas analysis with its major advantages of having very short response times of below 100ms and outstanding detection limits in the single digit pptv region. However, the quadrupole mass filter based instruments used so far cannot separate isobaric compounds due to lack of mass resolution. To overcome this problem Ionicon developed the so called PTR-TOF 8000 instrument, which couples the well established PTR ionization technique with a high resolution time-of-flight (TOF) mass analyzer. In contrast to a quadrupole based PTR-MS where only one nominal mass at a time can be monitored, the PTR-TOF acquires whole mass spectra in split-seconds at a resolution of up to 8.000 m/{delta}m (FWHM). As there might be applications where an enormous mass resolution is not necessarily needed, but the sensitivity has to be as high as possible, we now developed an instrument (called PTR-TOF 2000) that performs with an enhanced sensitivity at the expense of a somewhat lower mass resolution.

Featured Articles

Download Contributions to the International Conference on Proton Transfer Reaction Mass Spectrometry and Its Applications:

 

Selected PTR-MS related Reviews

F. Biasioli, C. Yeretzian, F. Gasperi, T. D. Märk: PTR-MS monitoring of VOCs and BVOCs in food science and technology, Trends in Analytical Chemistry 30 (7) (2011).
Link

J. de Gouw, C. Warneke, T. Karl, G. Eerdekens, C. van der Veen, R. Fall: Measurement of Volatile Organic Compounds in the Earth's Atmosphere using Proton-Transfer-Reaction Mass Spectrometry. Mass Spectrometry Reviews, 26 (2007), 223-257.
Link

W. Lindinger, A. Hansel, A. Jordan: Proton-transfer-reaction mass spectrometry (PTR–MS): on-line monitoring of volatile organic compounds at pptv levels, Chem. Soc. Rev. 27 (1998), 347-375.
Link

 

Lists with PTR-MS relevant publications of the University of Innsbruck can be found here: Atmospheric and indoor air chemistry, IMR, Environmental Physics and Nano-Bio-Physics

 

Download the latest version of the IONICON publication database as BibTeX.