Callback Service

Undefined

The world's leading PTR-MS company

Providing ultra-sensitive solutions for real-time trace gas analysis since 1998

Navigation

You are here

Scientific Articles - PTR-MS Bibliography

Welcome to the new IONICON scientific articles database!

Publications

Found 20 results
Title [ Year(Asc)]
Filters: Author is Sulzer, Philipp  [Clear All Filters]
2016
[1688] Breiev, K., K. M. M. Burseg, G. OConnell, E. Hartungen, S. S. Biel, X. Cahours, S. Colard, T. D. Maerk, and P. Sulzer, "An online method for the analysis of volatile organic compounds in electronic cigarette aerosol based on proton transfer reaction mass spectrometry", Rapid Commun. Mass Spectrom., vol. 30, pp. 691–697, Feb, 2016.
Link: http://dx.doi.org/10.1002/rcm.7487
Abstract
<p>Rationale Due to the recent rapid increase in electronic cigarette (e-cigarette) use worldwide, there is a strong scientific but also practical interest in analyzing e-cigarette aerosols. Most studies to date have used standardized but time-consuming offline technologies. Here a proof-of-concept for a fast online quantification setup based on proton transfer reaction mass spectrometry (PTR-MS) is presented. Methods The combination of a novel sampling interface with a time-of-flight PTR-MS instrument specially designed for three scenarios is introduced: (i) mainstream aerosol analysis (aerosol that the user inhales prior to exhalation), and analysis of exhaled breath following (ii) mouth-hold (no inhalation) and (iii) inhalation of e-cigarette aerosols. A double-stage dilution setup allows the various concentration ranges in these scenarios to be accessed. Results First, the instrument is calibrated for the three principal constituents of the e-cigarettes&#39; liquids, namely propylene glycol, vegetable glycerol and nicotine. With the double-stage dilution the instrument&#39;s dynamic range was easily adapted to cover the concentration ranges obtained in the three scenarios: 20&ndash;1100 ppmv for the mainstream aerosol characterisation; 4&ndash;300 ppmv for the mouth-hold; and 2 ppbv to 20 ppmv for the inhalation experiment. Conclusions It is demonstrated that the novel setup enables fast, high time resolution e-cigarette studies with online quantification. This enables the analysis and understanding of any puff-by-puff variations in e-cigarette aerosols. Large-scale studies involving a high number of volunteers will benefit from considerably higher sample throughput and shorter data processing times.</p>
2015
[1655] Materic, D., M. Lanza, P. Sulzer, J. Herbig, D. Bruhn, C. Turner, N. Mason, and V. Gauci, "Monoterpene separation by coupling proton transfer reaction time-of-flight mass spectrometry with fastGC", Analytical and Bioanalytical Chemistry, Aug, 2015.
Link: http://dx.doi.org/10.1007/s00216-015-8942-5
Abstract
<p>Proton transfer reaction mass spectrometry (PTR-MS) is a well-established technique for real-time analysis of volatile organic compounds (VOCs). Although it is extremely sensitive (with sensitivities of up to 4500 cps/ppbv, limits of detection &lt;1 pptv and the response times of approximately 100 ms), the selectivity of PTR-MS is still somewhat limited, as isomers cannot be separated. Recently, selectivity-enhancing measures, such as manipulation of drift tube parameters (reduced electric field strength) and using primary ions other than H3O+, such as NO+ and O2 +, have been introduced. However, monoterpenes, which belong to the most important plant VOCs, still cannot be distinguished so more traditional technologies, such as gas chromatography mass spectrometry (GC-MS), have to be utilised. GC-MS is very time consuming (up to 1 h) and cannot be used for real-time analysis. Here, we introduce a sensitive, near-to-real-time method for plant monoterpene research&mdash;PTR-MS coupled with fastGC. We successfully separated and identified six of the most abundant monoterpenes in plant studies (α- and β-pinenes, limonene, 3-carene, camphene and myrcene) in less than 80 s, using both standards and conifer branch enclosures (Norway spruce, Scots pine and black pine). Five monoterpenes usually present in Norway spruce samples with a high abundance were separated even when the compound concentrations were diluted to 20 ppbv. Thus, fastGC-PTR-ToF-MS was shown to be an adequate one-instrument solution for plant monoterpene research.</p>
[1711] Materic, D., M. Lanza, P. Sulzer, J. Herbig, D. Bruhn, C. Turner, N. Mason, and V. Gauci, "Monoterpene separation by coupling proton transfer reaction time-of-flight mass spectrometry with fastGC.", Anal Bioanal Chem, vol. 407, pp. 7757–7763, Oct, 2015.
Link: http://dx.doi.org/10.1007/s00216-015-8942-5
Abstract
<p>Proton transfer reaction mass spectrometry (PTR-MS) is a well-established technique for real-time analysis of volatile organic compounds (VOCs). Although it is extremely sensitive (with sensitivities of up to 4500 cps/ppbv, limits of detection &lt;1 pptv and the response times of approximately 100 ms), the selectivity of PTR-MS is still somewhat limited, as isomers cannot be separated. Recently, selectivity-enhancing measures, such as manipulation of drift tube parameters (reduced electric field strength) and using primary ions other than H3O(+), such as NO(+) and O2 (+), have been introduced. However, monoterpenes, which belong to the most important plant VOCs, still cannot be distinguished so more traditional technologies, such as gas chromatography mass spectrometry (GC-MS), have to be utilised. GC-MS is very time consuming (up to 1 h) and cannot be used for real-time analysis. Here, we introduce a sensitive, near-to-real-time method for plant monoterpene research-PTR-MS coupled with fastGC. We successfully separated and identified six of the most abundant monoterpenes in plant studies (α- and β-pinenes, limonene, 3-carene, camphene and myrcene) in less than 80 s, using both standards and conifer branch enclosures (Norway spruce, Scots pine and black pine). Five monoterpenes usually present in Norway spruce samples with a high abundance were separated even when the compound concentrations were diluted to 20 ppbv. Thus, fastGC-PTR-ToF-MS was shown to be an adequate one-instrument solution for plant monoterpene research.</p>
[1576] Lanza, M., J. W. Acton, P. Sulzer, K. Breiev, S. Juerschik, A. Jordan, E. Hartungen, G. Hanel, L. Maerk, T. D. Maerk, et al., "Selective reagent ionisation-time of flight-mass spectrometry: a rapid technology for the novel analysis of blends of new psychoactive substances", Journal of Mass Spectrometry, vol. 50, pp. 427–431, 2015.
Link: http://dx.doi.org/10.1002/jms.3514
Abstract
In this study we demonstrate the potential of selective reagent ionisation-time of flight-mass spectrometry for the rapid and selective identification of a popular new psychoactive substance blend called ‘synthacaine’, a mixture that is supposed to imitate the sensory and intoxicating effects of cocaine. Reactions with H3O+ result in protonated parent molecules which can be tentatively assigned to benzocaine and methiopropamine. However, by comparing the product ion branching ratios obtained at two reduced electric field values (90 and 170 Td) for two reagent ions (H3O+ and NO+) to those of the pure chemicals, we show that identification is possible with a much higher level of confidence then when relying solely on the m/z of protonated parent molecules. A rapid and highly selective analytical identification of the constituents of a recreational drug is particularly crucial to medical personnel for the prompt medical treatment of overdoses, toxic effects or allergic reactions. Copyright © 2015 John Wiley & Sons, Ltd.
[1638] Lanza, M., J. W Acton, P. Sulzer, K. Breiev, S. Jürschik, A. Jordan, E. Hartungen, G. Hanel, L. Märk, T. D. Märk, et al., "Selective reagent ionisation-time of flight-mass spectrometry: a rapid technology for the novel analysis of blends of new psychoactive substances.", J Mass Spectrom, vol. 50, pp. 427–431, Feb, 2015.
Link: http://dx.doi.org/10.1002/jms.3514
Abstract
<p>In this study we demonstrate the potential of selective reagent ionisation-time of flight-mass spectrometry for the rapid and selective identification of a popular new psychoactive substance blend called &#39;synthacaine&#39;, a mixture that is supposed to imitate the sensory and intoxicating effects of cocaine. Reactions with H3O(+) result in protonated parent molecules which can be tentatively assigned to benzocaine and methiopropamine. However, by comparing the product ion branching ratios obtained at two reduced electric field values (90 and 170 Td) for two reagent ions (H3O(+) and NO(+)) to those of the pure chemicals, we show that identification is possible with a much higher level of confidence then when relying solely on the m/z of protonated parent molecules. A rapid and highly selective analytical identification of the constituents of a recreational drug is particularly crucial to medical personnel for the prompt medical treatment of overdoses, toxic effects or allergic reactions.</p>
2014
[1642] W Acton, J., M. Lanza, B. Agarwal, S. Jürschik, P. Sulzer, K. Breiev, A. Jordan, E. Hartungen, G. Hanel, L. Märk, et al., "Headspace analysis of new psychoactive substances using a Selective Reagent Ionisation-Time of Flight-Mass Spectrometer.", Int J Mass Spectrom, vol. 360, pp. 28–38, Mar, 2014.
Link: http://dx.doi.org/10.1016/j.ijms.2013.12.009
Abstract
<p>The rapid expansion in the number and use of new psychoactive substances presents a significant analytical challenge because highly sensitive instrumentation capable of detecting a broad range of chemical compounds in real-time with a low rate of false positives is required. A Selective Reagent Ionisation-Time of Flight-Mass Spectrometry (SRI-ToF-MS) instrument is capable of meeting all of these requirements. With its high mass resolution (up to m/Δm of 8000), the application of variations in reduced electric field strength (E/N) and use of different reagent ions, the ambiguity of a nominal (monoisotopic) m/z is reduced and hence the identification of chemicals in a complex chemical environment with a high level of confidence is enabled. In this study we report the use of a SRI-ToF-MS instrument to investigate the reactions of H3O(+), O2 (+), NO(+) and Kr(+) with 10 readily available (at the time of purchase) new psychoactive substances, namely 4-fluoroamphetamine, methiopropamine, ethcathinone, 4-methylethcathinone, N-ethylbuphedrone, ethylphenidate, 5-MeO-DALT, dimethocaine, 5-(2-aminopropyl)benzofuran and nitracaine. In particular, the dependence of product ion branching ratios on the reduced electric field strength for all reagent ions was investigated and is reported here. The results reported represent a significant amount of new data which will be of use for the development of drug detection techniques suitable for real world scenarios.</p>
2013
[Sulzer2013a] Sulzer, P., B. Agarwal, S. Juerschik, M. Lanza, A. Jordan, E. Hartungen, G. Hanel, L. Märk, T. D. Märk, R. González-Méndez, et al., "Applications of switching reagent ions in proton transfer reaction mass spectrometric instruments for the improved selectivity of explosive compounds", International Journal of Mass Spectrometry, vol. 354–355: Elsevier, 2013.
Link: http://www.sciencedirect.com/science/article/pii/S1387380613001735
Abstract
<p>Here we demonstrate the use of a switchable reagent ion proton transfer reaction mass spectrometry (SRI-PTR-MS) instrument to improve the instrument&#39;s selectivity for the detection of the explosive compounds 2,4,6 trinitrotoluene (TNT), 1,3,5 trinitrobenzene (TNB), pentaerythritol tetranitrate (PETN), and cyclotrimethylenetrinitramine (RDX). Selectivity is improved owing to the production of different product ions resulting from changes in the reagent ion-molecule chemistry. To be of use as an analytical tool for homeland security applications, it is important that the reagent ions (and hence product ions) can be rapidly changed (within seconds) from H3O+ to another dominant ion species if the technology is to be acceptable. This paper presents measurements that show how it is possible to rapidly switch the reagent ion from H3O+ to either O2+ or NO+ to enhance selectivity for the detection of the four explosives named above. That switching reagent ions can be done quickly results from the fact that the recombination energies of O2+ and NO+ are less than the ionisation potential of H2O, i.e. charge transfer cannot occur which otherwise would result in ions that can react efficiently with water (e.g. H2O+ + H2O &rarr; H3O+ + OH) leading to H3O+ becoming the dominant reagent ion. Reaction processes observed are non-dissociative charge transfer (O2+ with TNT and TNB), dissociative charge transfer (O2+ with TNT) and adduct formation (NO+ with PETN and RDX). O2+ is found to be unreactive with PETN and RDX, and under the conditions operating in the reaction region of the PTR-MS only a low signal associated with NO+&middot;TNT was observed. No NO+&middot;TNB was detected.</p>
[Lanza2013] Lanza, M., J. W. Acton, S. Jürschik, P. Sulzer, K. Breiev, A. Jordan, E. Hartungen, G. Hanel, L. Märk, C. A. Mayhew, et al., "Distinguishing two isomeric mephedrone substitutes with selective reagent ionisation mass spectrometry (SRI-MS)", Journal of Mass Spectrometry, vol. 48, no. 9, pp. 1015–1018, 2013.
Link: http://dx.doi.org/10.1002/jms.3253
Abstract
The isomers 4-methylethcathinone and N-ethylbuphedrone are substitutes for the recently banned drug mephedrone. We find that with conventional proton transfer reaction mass spectrometry (PTR-MS), it is not possible to distinguish between these two isomers, because essentially for both substances, only the protonated molecules are observed at a mass-to-charge ratio of 192 (C12H18NO+). However, when utilising an advanced PTR-MS instrument that allows us to switch the reagent ions (selective reagent ionisation) from H3O+ (which is commonly used in PTR-MS) to NO+, O2+ and Kr+, characteristic product (fragment) ions are detected: C4H10N+ (72 Da) for 4-methylethcathinone and C5H12N+ (86 Da) for N-ethylbuphedrone; thus, selective reagent ionisation MS proves to be a powerful tool for fast detection and identification of these compounds. Copyright © 2013 John Wiley & Sons, Ltd.
[Kassebacher2013] Kassebacher, T., P. Sulzer, S. Juerschik, E. Hartungen, A. Jordan, A. Edtbauer, S. Feil, G. Hanel, S. Jaksch, L. Maerk, et al., "Investigations of chemical warfare agents and toxic industrial compounds with proton-transfer-reaction mass spectrometry for a real-time threat monitoring scenario.", Rapid Commun Mass Spectrom, vol. 27, no. 2: Austria., pp. 325–332, Jan, 2013.
Link: http://dx.doi.org/10.1002/rcm.6456
Abstract
Security and protection against terrorist attacks are major issues in modern society. One especially challenging task is the monitoring and protection of air conditioning and heating systems of buildings against terrorist attacks with toxic chemicals. As existing technologies have low selectivity, long response times or insufficient sensitivity, there is a need for a novel approach such as we present here.We have analyzed various chemical warfare agents (CWAs) and/or toxic industrial compounds (TICs) and related compounds, namely phosgene, diphosgene, chloroacetone, chloroacetophenone, diisopropylaminoethanol, and triethyl phosphate, utilizing a high-resolution proton-transfer-reaction time-of-flight mass spectrometry (PTR-TOFMS) instrument with the objective of finding key product ions and their intensities, which will allow a low-resolution quadrupole mass spectrometry based PTR-MS system to be used with high confidence in the assignment of threat agents in the atmosphere.We obtained high accuracy PTR-TOFMS mass spectra of the six compounds under study at two different values for the reduced electric field in the drift tube (E/N). From these data we have compiled a table containing product ions, and isotopic and E/N ratios for highly selective threat compound detection with a compact and cost-effective quadrupole-based PTR-MS instrument. Furthermore, using chloroacetophenone (tear gas), we demonstrated that this instrument's response is highly linear in the concentration range of typical Acute Exposure Guideline Levels (AEGLs).On the basis of the presented results it is possible to develop a compact and cost-effective PTR-QMS instrument that monitors air supply systems and triggers an alarm as soon as the presence of a threat agent is detected. We hope that this real-time surveillance device will help to seriously improve safety and security in environments vulnerable to terrorist attacks with toxic chemicals.
[Lindinger2013] Lindinger, C., L. Märk, P. Sulzer, S. Juerschik, B. Agarwal, C. A. Mayhew, and T. D. Märk, "Proton-Transfer-Reaction Mass Spectrometry: Increased Selectivity in Explosives and Designer Drugs Detection", : IONICON Analytik, 2013.
Link: http://www.ionicon.com/sites/default/files/uploads/doc/poster_ionicon_pittcon_2013_explosives_and_designer_drugs_detection.pdf
[Jordan2013] Jordan, A., E. Hartungen, A. Edtbauer, S. Feil, G. Hanel, P. Sulzer, S. Juerschik, S. Jaksch, L. Maerk, and T. D. Maerk, "Ultra-high sensitivity Proton-Transfer-Reaction Time-of-Flight Mass Spectrometry (PTR-TOFMS)", CONFERENCE SERIES, pp. 80, 2013.
Link: http://www.ionicon.com/sites/default/files/uploads/doc/contributions_ptr_ms_Conference_6.pdf
2012
[Sulzer2012a] Sulzer, P., S. Juerschik, B. Agarwal, T. Kassebacher, E. Hartungen, A. Edtbauer, F. Petersson, J. Warmer, G. Holl, D. Perry, et al., "Designer Drugs and Trace Explosives Detection with the Help of Very Recent Advancements in Proton-Transfer-Reaction Mass Spectrometry (PTR-MS)", Future Security: Springer, pp. 366–375, 2012.
Link: http://link.springer.com/chapter/10.1007/978-3-642-33161-9_55
Abstract
At the "Future Security 2011" we presented an overview of our studies on the "Detection and Identification of Illicit and Hazardous Substances with Proton-Transfer-Reaction Mass Spectrometry (PTR-MS)" including first results on explosives, chemical warfare agents and illicit and prescribed drugs detection. Since then we have considerably extended these preliminary studies to the detection of defined traces of some of the most common explosives, namely TNT, PETN, TATP, and DATP deposited into aluminum foam bodies, and to the detection of a number of novel and widely unknown designer drugs: ethylphenidate, 4-fluoroamphetamine and dimethocaine. Moreover, we have dramatically improved our time-of-flight based PTR-MS instruments by substantially increasing their sensitivity and hence lowering the detection limit, making them even more suitable and applicable to threat agents with extremely low vapour pressures. Data from measurements on certified gas standards are presented in order to underline these statements. The data demonstrate that, in comparison to the first generation instruments, a gain of one order of magnitude in terms of sensitivity and detection limit has been obtained.
[Kassebacher2012] Kassebacher, T., P. Sulzer, S. Juerschik, B. Agarwal, F. Petersson, E. Hartungen, H. Seehauser, and T. D. Maerk, "Detecting and Quantifying Toxic Industrial Compounds (TICs) with Proton-Transfer-Reaction Mass Spectrometry (PTR-MS)", Future Security: Springer, pp. 438–447, 2012.
Link: http://link.springer.com/chapter/10.1007/978-3-642-33161-9_62
Abstract
In the course of the FP7-SEC project "SPIRIT" (Safety and Protection of built Infrastructure to Resist Integral Threats) we focused our research with Proton-Transfer-Reaction Mass Spectrometry (PTR-MS) on C-agents, specifically Toxic Industrial Compounds (TICs). Most TICs are readily available and represent a considerable threat when used in terroristic attacks. We show the principal procedure of PTR-MS detection measurements on two chemicals, namely phosgene and chloroacetone. With studies of the former we want to point out principle differences between measurements on a quadrupole mass filter based and a Time-of-Flight-based PTR-MS instrument and point out the respective benefits and drawbacks. For the latter we present the results of a diluted headspace measurement and illustrate the connection with security standards in buildings.
[Sulzer2012c] Sulzer, P., A. Edtbauer, E. Hartungen, S. Juerschik, A. Jordan, G. Hanel, S. Feil, S. Jaksch, L. Märk, and T. D. Märk, "From conventional proton-transfer-reaction mass spectrometry (PTR-MS) to universal trace gas analysis", International Journal of Mass Spectrometry, vol. 321: Elsevier, pp. 66–70, 2012.
Link: http://www.sciencedirect.com/science/article/pii/S1387380612001704
Abstract
We present here a slightly modified PTR-MS instrument that is not only capable to ionize trace compounds in air via proton-transfer-reactions (PTR) but is also able to ionize via charge-transfer-reactions (CTR) with help of reagent ions (Kr+ in particular) possessing higher ionization energies than common air constituents. This means that with minor adaptations a common PTR-MS instrument can be used for the analysis of nearly all available substance classes by using both PTR and/or CTR ionization. Especially in environmental research, the field of application where PTR-MS is used most widely, now not only trace volatile organic compounds (benzene, toluene, etc.) but additionally also very important (inorganic) substances, such as CO, CO2, CH4, NOx, and SO2, can be detected and quantified with the same instrument. As all ionizing agents are produced in a hollow cathode discharge ion source with good purity no additional mass filter is needed for reagent ion selection (as in other analytical methods employed) and remaining reagent ion impurities can be clearly distinguished from isobaric sample compounds due to the high mass resolution of the time-of-flight mass spectrometer used in the present PTR-MS instrument (PTR-TOF 8000). We present data obtained with various gas standards ranging from a “classical” PTR-MS aromatics mixture to samples containing molecules possessing ionization energies all the way up to 14 eV (CO).
[Maerk2012] Märk, L., A. Jordan, C. Lindinger, E. Hartungen, A. Edtbauer, S. Juerschik, P. Sulzer, and T. D. Märk, "More than one order of magnitude higher sensitivities with Proton-Transfer-Reaction Time-of-Flight Mass Spectrometry", : IONICON Analytik, 2012.
Link: http://www.ionicon.com/sites/default/files/uploads/doc/poster_ionicon_asms_ptr_tofms_series_performance_improvements.pdf
[Sulzer2012] Sulzer, P., F. Petersson, B. Agarwal, K. H. Becker, S. Juerschik, T. D. Maerk, D. Perry, P. Watts, and C. A. Mayhew, "Proton transfer reaction mass spectrometry and the unambiguous real-time detection of 2,4,6 trinitrotoluene.", Anal Chem, vol. 84, no. 9: Ionicon Analytik Gesellschaft m.b.H., Eduard-Bodem-Gasse 3, A-6020 Innsbruck, Austria., pp. 4161–4166, May, 2012.
Link: http://dx.doi.org/10.1021/ac3004456
Abstract
Fears of terrorist attacks have led to the development of various technologies for the real-time detection of explosives, but all suffer from potential ambiguities in the assignment of threat agents. Using proton transfer reaction mass spectrometry (PTR-MS), an unusual bias dependence in the detection sensitivity of 2,4,6 trinitrotoluene (TNT) on the reduced electric field (E/N) has been observed. For protonated TNT, rather than decreasing signal intensity with increasing E/N, which is the more usual sensitivity pattern observed in PTR-MS studies, an anomalous behavior is first observed, whereby the signal intensity initially rises with increasing E/N. We relate this to unexpected ion-molecule chemistry based upon comparisons of measurements taken with related nitroaromatic compounds (1,3,5 trinitrobenzene, 1,3 dinitrobenzene, and 2,4 dinitrotoluene) and electronic structure calculations. This dependence provides an easily measurable signature that can be used to provide a rapid highly selective analytical procedure to minimize false positives for the detection of TNT. This has major implications for Homeland Security and, in addition, has the potential of making instrumentation cost-effective for use in security areas. This study shows that an understanding of fundamental ion-molecule chemistry occurring in low-pressure drift tubes is needed to exploit selectivity and sensitivity for analytical purposes.
[Juerschik2012] Juerschik, S., B. Agarwal, T. Kassebacher, P. Sulzer, C. A. Mayhew, and T. D. Märk, "Rapid and facile detection of four date rape drugs in different beverages utilizing proton transfer reaction mass spectrometry (PTR-MS).", J Mass Spectrom, vol. 47, no. 9: IONICON Analytik GmbH., Eduard-Bodem-Gasse 3, 6020, Innsbruck, Austria., pp. 1092–1097, Sep, 2012.
Link: http://dx.doi.org/10.1002/jms.2993
Abstract
In this work, we illustrate the application of proton transfer reaction mass spectrometry (PTR-MS) in the field of food and drink safety. We present proof-of-principle measurements of four different drinks (water, tea, red wine and white wine) each spiked separately with four different date rape drugs (chloral hydrate, tricholorethanol, γ-butyrolactone and butanediol). At first, the ideal PTR-MS operating conditions (reduced electric field strength and monitoring the most abundant [fragment] ion) for detection of the drugs were determined utilizing a time-of-flight-based PTR-MS instrument. We then dissolved small quantities of the drugs (below the activation threshold for effects on humans) into the various types of drinks and detected them using a quadrupole-based PTR-MS instrument via two different sampling methods: (1) dynamic headspace sampling and (2) direct liquid injection. Both methods have their advantages and drawbacks. Only with dynamic headspace sampling can rape drug contaminations be detected within a timeframe of seconds, and therefore, this method is the most promising use of PTR-MS as a fast, sensitive and selective monitor for the detection of food and drink contamination.
2011
[Juerschik2011] Juerschik, S., P. Sulzer, A. Jordan, L. Maerk, and M. D Tilmann, "Sprengstoffe und Drogen–PTR-MS in der Spurenanalytik", Nachrichten aus der Chemie, vol. 59, no. 11, pp. 1087–1088, 2011.
Link: http://www.degruyter.com/view/j/nachrchem.2011.59.11/nachrchem.2011.59.11.1087/nachrchem.2011.59.11.1087.xml
2010
[Jordan2010] Jordan, A., P. Sulzer, S. Juerschik, S. Jaksch, G. Hanel, E. Hartungen, H. Seehauser, L. Maerk, S. Haidacher, R. Schottkowsky, et al., "Extremely high mass resolution and sensitivity-comparison of two novel proton transfer reaction time-of-flight mass spectrometers (PTR-TOFMS)", Verhandlungen der Deutschen Physikalischen Gesellschaft, vol. -, no. Hanver 2010 issue, pp. -, 2010.
Link: https://www.etde.org/etdeweb/details_open.jsp?osti_id=21329230
Abstract
Since many years PTR-MS is a well established technique in trace gas analysis with its major advantages of having very short response times of below 100ms and outstanding detection limits in the single digit pptv region. However, the quadrupole mass filter based instruments used so far cannot separate isobaric compounds due to lack of mass resolution. To overcome this problem Ionicon developed the so called PTR-TOF 8000 instrument, which couples the well established PTR ionization technique with a high resolution time-of-flight (TOF) mass analyzer. In contrast to a quadrupole based PTR-MS where only one nominal mass at a time can be monitored, the PTR-TOF acquires whole mass spectra in split-seconds at a resolution of up to 8.000 m/{delta}m (FWHM). As there might be applications where an enormous mass resolution is not necessarily needed, but the sensitivity has to be as high as possible, we now developed an instrument (called PTR-TOF 2000) that performs with an enhanced sensitivity at the expense of a somewhat lower mass resolution.
2009
[Petersson2009] Petersson, F., P. Sulzer, C. A. Mayhew, P. Watts, A. Jordan, L. Märk, and T. D. Märk, "Real-time trace detection and identification of chemical warfare agent simulants using recent advances in proton transfer reaction time-of-flight mass spectrometry.", Rapid Commun Mass Spectrom, vol. 23, no. 23: Institut für Ionenphysik und Angewandte Physik, Leopold Franzens Universität Innsbruck, Technikerstr. 25, A-6020 Innsbruck, Austria., pp. 3875–3880, Dec, 2009.
Link: http://dx.doi.org/10.1002/rcm.4334
Abstract
This work demonstrates for the first time the potential of using recent developments in proton transfer reaction mass spectrometry for the rapid detection and identification of chemical warfare agents (CWAs) in real-time. A high-resolution (m/Deltam up to 8000) and high-sensitivity (approximately 50 cps/ppbv) proton transfer reaction time-of-flight mass spectrometer (PTR-TOF 8000 from Ionicon Analytik GmBH) has been successfully used to detect a number of CWA simulants at room temperature; namely dimethyl methylphosphonate, diethyl methylphosphonate, diisopropyl methylphosphonate, dipropylene glycol monomethyl ether and 2-chloroethyl ethyl sulfide. Importantly, we demonstrate in this paper the potential to identify CWAs with a high level of confidence in complex chemical environments, where multiple threat agents and interferents could also be present in trace amounts, thereby reducing the risk of false positives. Instantaneous detection and identification of trace quantities of chemical threats using proton transfer reaction mass spectrometry could form the basis for a timely warning system capability with greater precision and accuracy than is currently provided by existing analytical technologies.

Featured Articles

Download Contributions to the International Conference on Proton Transfer Reaction Mass Spectrometry and Its Applications:

 

Selected PTR-MS related Reviews

F. Biasioli, C. Yeretzian, F. Gasperi, T. D. Märk: PTR-MS monitoring of VOCs and BVOCs in food science and technology, Trends in Analytical Chemistry 30 (7) (2011).
Link

J. de Gouw, C. Warneke, T. Karl, G. Eerdekens, C. van der Veen, R. Fall: Measurement of Volatile Organic Compounds in the Earth's Atmosphere using Proton-Transfer-Reaction Mass Spectrometry. Mass Spectrometry Reviews, 26 (2007), 223-257.
Link

W. Lindinger, A. Hansel, A. Jordan: Proton-transfer-reaction mass spectrometry (PTR–MS): on-line monitoring of volatile organic compounds at pptv levels, Chem. Soc. Rev. 27 (1998), 347-375.
Link

 

Lists with PTR-MS relevant publications of the University of Innsbruck can be found here: Atmospheric and indoor air chemistry, IMR, Environmental Physics and Nano-Bio-Physics

 

Download the latest version of the IONICON publication database as BibTeX.