Scientific Articles - PTR-MS Bibliography

Welcome to the new IONICON scientific articles database!

Publications

Found 2 results
Title [ Year(Asc)]
Filters: Author is Jankowski, Mikolaj Jan  [Clear All Filters]
2014
[1560] Jankowski, M. Jan, R. Olsen, C. Nielsen, Y. Thomassen, and P. Molander, "The applicability of proton transfer reaction-mass spectrometry (PTR-{MS}) for determination of isocyanic acid ({ICA}) in work room atmospheres", Environmental Science: Processes & Impacts, 2014.
Link: http://dx.doi.org/10.1039/C4EM00363B
Abstract
<p>A method is presented for the real-time quantitative determination of isocyanic acid (ICA) in air using proton transfer reaction-mass spectrometry (PTR-MS). Quantum mechanical calculations were performed to establish the ion-polar molecule reaction rate of ICA and other isocyanates. The PTR-MS was calibrated against different ICA air concentrations and humidity conditions using Fourier transform-infrared spectroscopy (FT-IR) as quantitative reference. Based on these experiments a simple humidity dependant model was derived for correction of the PTR-MS response for ICA. The corrected PTR-MS data was linearly correlated (R2 &gt; 0.99) with the data acquired by FT-IR. The PTR-MS instrumental limit of detection (LOD) for ICA was 2.3 ppb. Humid atmospheres resulted in LODs of 3.4 and 7.8 ppb, at an absolute humidity (AH) of 4.0 and 15.5 g m-3, respectively. Furthermore, off-line sampling using denuder and impinger samplers using di-n-butylamine (DBA) as derivatization reagent was compared with PTR-MS measurements in a dynamically generated standard ICA atmosphere. Denuder (n = 4) and impinger (n = 4) sampling subsequent to liquid chromatography mass spectrometry (LC-MS) determination compared to corrected PTR-MS data resulted in recoveries of 79.6 (8.1 % RSD) and 99.9 (9.3 % RSD) %, respectively. Measurements of ICA from thermally decomposed cured 1,6-hexamethylene diisocyanate (HDI)-paint was performed used PTR-MS and denuder (n = 3) sampling. The relation between the average ICA responses using denuders (34.4 ppb) and PTR-MS (42.6 ppb) was 80.6 %, which coincided well with the relative recovery obtained from the controlled laboratory experiments using dynamically generated ICA atmospheres (79.6 %). The variability in ICA air concentration during the welding process (170 % RSDPTR-MS) illustrated the need for real-time measurements.</p>
[1636] Jankowski, M. Jan, R. Olsen, C. Jørgen Nielsen, Y. Thomassen, and P. Molander, "The applicability of proton transfer reaction-mass spectrometry (PTR-MS) for determination of isocyanic acid (ICA) in work room atmospheres.", Environ Sci Process Impacts, vol. 16, pp. 2423–2431, 2014.
Link: http://dx.doi.org/10.1039/c4em00363b
Abstract
<p>A method is presented for the real-time quantitative determination of isocyanic acid (ICA) in air using proton transfer reaction-mass spectrometry (PTR-MS). Quantum mechanical calculations were performed to establish the ion-polar molecule reaction rate of ICA and other isocyanates. The PTR-MS was calibrated against different ICA air concentrations and humidity conditions using Fourier transform-infrared spectroscopy (FT-IR) as quantitative reference. Based on these experiments a simple humidity dependant model was derived for correction of the PTR-MS response for ICA. The corrected PTR-MS data was linearly correlated (R(2) &gt; 0.99) with the data acquired by FT-IR. The PTR-MS instrumental limit of detection (LOD) for ICA was 2.3 ppb. Humid atmospheres resulted in LODs of 3.4 and 7.8 ppb, at an absolute humidity (AH) of 4.0 and 15.5 g m(-3), respectively. Furthermore, off-line sampling using denuder and impinger samplers using di-n-butylamine (DBA) as derivatization reagent was compared with PTR-MS measurements in a dynamically generated standard ICA atmosphere. Denuder (n = 4) and impinger (n = 4) sampling subsequent to liquid chromatography mass spectrometry (LC-MS) determination compared to corrected PTR-MS data resulted in recoveries of 79.6 (8.1% RSD) and 99.9 (9.3% RSD) %, respectively. Measurements of ICA from thermally decomposed cured 1,6-hexamethylene diisocyanate (HDI)-paint was performed using PTR-MS and denuder (n = 3) sampling. The relation between the average ICA responses using denuders (34.4 ppb) and PTR-MS (42.6 ppb) was 80.6%, which coincided well with the relative recovery obtained from the controlled laboratory experiments using dynamically generated ICA atmospheres (79.6%). The variability in ICA air concentration during the welding process (170% RSDPTR-MS) illustrated the need for real-time measurements.</p>

Featured Articles

Download Contributions to the International Conference on Proton Transfer Reaction Mass Spectrometry and Its Applications:

 

Selected PTR-MS related Reviews

F. Biasioli, C. Yeretzian, F. Gasperi, T. D. Märk: PTR-MS monitoring of VOCs and BVOCs in food science and technology, Trends in Analytical Chemistry 30 (7) (2011).
Link

J. de Gouw, C. Warneke, T. Karl, G. Eerdekens, C. van der Veen, R. Fall: Measurement of Volatile Organic Compounds in the Earth's Atmosphere using Proton-Transfer-Reaction Mass Spectrometry. Mass Spectrometry Reviews, 26 (2007), 223-257.
Link

W. Lindinger, A. Hansel, A. Jordan: Proton-transfer-reaction mass spectrometry (PTR–MS): on-line monitoring of volatile organic compounds at pptv levels, Chem. Soc. Rev. 27 (1998), 347-375.
Link

 

Lists with PTR-MS relevant publications of the University of Innsbruck can be found here: Atmospheric and indoor air chemistry, IMR, Environmental Physics and Nano-Bio-Physics

 

Download the latest version of the IONICON publication database as BibTeX.