Callback Service

Undefined

The world's leading PTR-MS company

Providing ultra-sensitive solutions for real-time trace gas analysis since 1998

Navigation

You are here

Scientific Articles - PTR-MS Bibliography

Welcome to the new IONICON scientific articles database!

Publications

Found 1 results
Title [ Year(Asc)]
Filters: Author is Fuhrmann, F.  [Clear All Filters]
2014
[1532] Schripp, T.., S.. Etienne, C.. Fauck, F.. Fuhrmann, L.. Märk, and T.. Salthammer, "Application of proton-transfer-reaction-mass-spectrometry for Indoor Air Quality research", Indoor Air, vol. 24, pp. 178–189, 2014.
Link: http://dx.doi.org/10.1111/ina.12061
Abstract
<p>In the field of Indoor Air Quality research, the measurement of volatile organic compounds (VOCs) demands instruments that are rapid, mobile, robust, highly sensitive and allow for simultaneous monitoring of multiple compounds. These instruments should also compensate for possible interferences from permanent gases and air humidity. Proton-transfer-reaction-mass-spectrometry (PTR-MS) has proved to be a valuable and promising technique that fits the mentioned requirements for a suitable online measuring device. In this study, five exemplary applications of PTR-MS are described: (i) release of paint additives during drying process, (ii) emission of VOCs from active hardcopy devices, (iii) reference material evaluation, (iv) diffusion studies, and (v) emission testing of building products. The examples are selected to illustrate possibilities and limitations of the PTR technique in this field of research. The quadruple-based PTR-QMS was able to determine the emission characteristics during the experiments, especially in case of depleting emission sources (e.g., reference material). This allows for chemometrical analysis of the measured release patterns and detection of underlying processes. However, PTR-QMS reaches a functional limit in case of compound identification. If identification of VOCs is necessary, the measurements need to be accompanied by GC/MS analytics or a PTR instrument with higher mass-resolution (e.g., PTR-TOF-MS).</p>

Featured Articles

Download Contributions to the International Conference on Proton Transfer Reaction Mass Spectrometry and Its Applications:

 

Selected PTR-MS related Reviews

F. Biasioli, C. Yeretzian, F. Gasperi, T. D. Märk: PTR-MS monitoring of VOCs and BVOCs in food science and technology, Trends in Analytical Chemistry 30 (7) (2011).
Link

J. de Gouw, C. Warneke, T. Karl, G. Eerdekens, C. van der Veen, R. Fall: Measurement of Volatile Organic Compounds in the Earth's Atmosphere using Proton-Transfer-Reaction Mass Spectrometry. Mass Spectrometry Reviews, 26 (2007), 223-257.
Link

W. Lindinger, A. Hansel, A. Jordan: Proton-transfer-reaction mass spectrometry (PTR–MS): on-line monitoring of volatile organic compounds at pptv levels, Chem. Soc. Rev. 27 (1998), 347-375.
Link

 

Lists with PTR-MS relevant publications of the University of Innsbruck can be found here: Atmospheric and indoor air chemistry, IMR, Environmental Physics and Nano-Bio-Physics

 

Download the latest version of the IONICON publication database as BibTeX.