Scientific Articles - PTR-MS Bibliography

Welcome to the new IONICON scientific articles database!

Publications

Found 7 results
Title [ Year(Asc)]
Filters: Author is Miekisch, Wolfram  [Clear All Filters]
2016
[1735] Sukul, P., J. K. Schubert, P. Oertel, S. Kamysek, K. Taunk, P. Trefz, and W. Miekisch, "FEV manoeuvre induced changes in breath VOC compositions: an unconventional view on lung function tests", Scientific Reports, vol. 6, pp. 28029, Jun, 2016.
Link: http://dx.doi.org/10.1038/srep28029
Abstract
Breath volatile organic compound (VOC) analysis can open a non-invasive window onto pathological and metabolic processes in the body. Decades of clinical breath-gas analysis have revealed that changes in exhaled VOC concentrations are important rather than disease specific biomarkers. As physiological parameters, such as respiratory rate or cardiac output, have profound effects on exhaled VOCs, here we investigated VOC exhalation under respiratory manoeuvres. Breath VOCs were monitored by means of real-time mass-spectrometry during conventional FEV manoeuvres in 50 healthy humans. Simultaneously, we measured respiratory and hemodynamic parameters noninvasively. Tidal volume and minute ventilation increased by 292 and 171% during the manoeuvre. FEV manoeuvre induced substance specific changes in VOC concentrations. pET-CO2 and alveolar isoprene increased by 6 and 21% during maximum exhalation. Then they decreased by 18 and 37% at forced expiration mirroring cardiac output. Acetone concentrations rose by 4.5% despite increasing minute ventilation. Blood-borne furan and dimethyl-sulphide mimicked isoprene profile. Exogenous acetonitrile, sulphides, and most aliphatic and aromatic VOCs changed minimally. Reliable breath tests must avoid forced breathing. As isoprene exhalations mirrored FEV performances, endogenous VOCs might assure quality of lung function tests. Analysis of exhaled VOC concentrations can provide additional information on physiology of respiration and gas exchange.
2015
[1715] Sukul, P., P. Trefz, S. Kamysek, J. K. Schubert, and W. Miekisch, "Instant effects of changing body positions on compositions of exhaled breath.", J Breath Res, vol. 9, pp. 047105, Dec, 2015.
Link: http://dx.doi.org/10.1088/1752-7155/9/4/047105
Abstract
<p>Concentrations of exhaled volatile organic compounds (VOCs) may depend not only on biochemical or pathologic processes but also on physiological parameters. As breath sampling may be done in different body positions, effects of the sampling position on exhaled VOC concentrations were investigated by means of real-time mass spectrometry. Breaths from 15 healthy volunteers were analyzed in real-time by PTR-ToF-MS-8000 during paced breathing (12/min) in a continuous side-stream mode. We applied two series of body positions (setup 1: sitting, standing, supine, and sitting; setup 2: supine, left lateral, right lateral, prone, and supine). Each position was held for 2&thinsp;min. Breath VOCs were quantified in inspired and alveolar air by means of a custom-made algorithm. Parallel monitoring of hemodynamics and capnometry was performed noninvasively. In setup 1, when compared to the initial sitting position, normalized mean concentrations of isoprene, furan, and acetonitrile decreased by 24%, 26%, and 9%, respectively, during standing and increased by 63%, 36%, and 10% during lying mirroring time profiles of stroke volume and pET-CO2. In contrast, acetone and H2S concentrations remained almost constant. In setup 2, when compared to the initial supine position, mean alveolar concentrations of isoprene and furan increased significantly up to 29% and 16%, respectively, when position was changed from lying on the right side to the prone position. As cardiac output and stroke volume decreased at that time, the reasons for the observed concentrations changes have to be linked to the ventilation/perfusion ratio or compartmental distribution rather than to perfusion alone. During final postures, all VOC concentrations, hemodynamics, and pET-CO2 returned to baseline. Exhaled blood-borne VOC profiles changed due to body postures. Changes depended on cardiac stroke volume, origin, compartmental distribution and physico-chemical properties of the substances. Patients&#39; positions and cardiac output have to be controlled when concentrations of breath VOCs are to be interpreted in terms of biomarkers.</p>
2013
[1699] Trefz, P., M. Schmidt, P. Oertel, J. Obermeier, B. Brock, S. Kamysek, J. Dunkl, R. Zimmermann, J. K. Schubert, and W. Miekisch, "Continuous real time breath gas monitoring in the clinical environment by proton-transfer-reaction-time-of-flight-mass spectrometry.", Anal Chem, vol. 85, pp. 10321–10329, Nov, 2013.
Link: http://dx.doi.org/10.1021/ac402298v
Abstract
<p>Analysis of volatile organic compounds (VOCs) in breath holds great promise for noninvasive diagnostic applications. However, concentrations of VOCs in breath may change quickly, and actual and previous uptakes of exogenous substances, especially in the clinical environment, represent crucial issues. We therefore adapted proton-transfer-reaction-time-of-flight-mass spectrometry for real time breath analysis in the clinical environment. For reasons of medical safety, a 6 m long heated silcosteel transfer line connected to a sterile mouth piece was used for breath sampling from spontaneously breathing volunteers and mechanically ventilated patients. A time resolution of 200 ms was applied. Breath from mechanically ventilated patients was analyzed immediately after cardiac surgery. Breath from 32 members of staff was analyzed in the post anesthetic care unit (PACU). In parallel, room air was measured continuously over 7 days. Detection limits for breath-resolved real time measurements were in the high pptV/low ppbV range. Assignment of signals to alveolar or inspiratory phases was done automatically by a matlab-based algorithm. Quickly and abruptly occurring changes of patients&#39; clinical status could be monitored in terms of breath-to-breath variations of VOC (e.g. isoprene) concentrations. In the PACU, room air concentrations mirrored occupancy. Exhaled concentrations of sevoflurane strongly depended on background concentrations in all participants. In combination with an optimized inlet system, the high time and mass resolution of PTR-ToF-MS provides optimal conditions to trace quick changes of breath VOC profiles and to assess effects from the clinical environment.</p>
[Pleil2013] Pleil, J. D., W. Miekisch, T. H. Risby, M. C. Madden, and J. R. Sobus, "Meeting reports for 2013: recent advances in breath biomarker research", Journal of breath research, vol. 7, no. 2: IOP Publishing, pp. 029001, 2013.
Link: http://iopscience.iop.org/1752-7163/7/2/029001
2011
[Kamysek2011] Kamysek, S., P. Fuchs, H. Schwoebel, J. P. Roesner, S. Kischkel, K. Wolter, C. Loeseken, J. K. Schubert, and W. Miekisch, "Drug detection in breath: effects of pulmonary blood flow and cardiac output on propofol exhalation.", Anal Bioanal Chem, vol. 401, no. 7: Department of Anesthesiology and Intensive Care, University of Rostock, Schillingallee 35, 18057 Rostock, Germany., pp. 2093–2102, Oct, 2011.
Link: http://dx.doi.org/10.1007/s00216-011-5099-8
Abstract
Breath analysis could offer a non-invasive means of intravenous drug monitoring if robust correlations between drug concentrations in breath and blood can be established. In this study, propofol blood and breath concentrations were determined in an animal model under varying physiological conditions. Propofol concentrations in breath were determined by means of two independently calibrated analytical methods: continuous, real-time proton transfer reaction mass spectrometry (PTR-MS) and discontinuous solid-phase micro-extraction coupled with gas chromatography mass spectrometry (SPME-GC-MS). Blood concentrations were determined by means of SPME-GC-MS. Effects of changes in pulmonary blood flow resulting in a decreased cardiac output (CO) and effects of dobutamine administration resulting in an increased CO on propofol breath concentrations and on the correlation between propofol blood and breath concentrations were investigated in seven acutely instrumented pigs. Discontinuous propofol determination in breath by means of alveolar sampling and SPME-GC-MS showed good agreement (R(2)=0.959) with continuous alveolar real-time measurement by means of PTR-MS. In all investigated animals, increasing cardiac output led to a deterioration of the relationship between breath and blood propofol concentrations (R(2)=0.783 for gas chromatography-mass spectrometry and R(2)=0.795 for PTR-MS). Decreasing pulmonary blood flow and cardiac output through banding of the pulmonary artery did not significantly affect the relationship between propofol breath and blood concentrations (R(2)>0.90). Estimation of propofol blood concentrations from exhaled alveolar concentrations seems possible by means of different analytical methods even when cardiac output is decreased. Increases in cardiac output preclude prediction of blood propofol concentration from exhaled concentrations.
[Schwoebel2011] Schwoebel, H., R. Schubert, M. Sklorz, S. Kischkel, R. Zimmermann, J. K. Schubert, and W. Miekisch, "Phase-resolved real-time breath analysis during exercise by means of smart processing of PTR-MS data.", Anal Bioanal Chem, vol. 401, no. 7: Department of Anaesthesia and Intensive Care Medicine, University of Rostock, Schillingallee 70, 18057 Rostock, Germany., pp. 2079–2091, Oct, 2011.
Link: http://dx.doi.org/10.1007/s00216-011-5173-2
Abstract
Separation of inspiratory, mixed expired and alveolar air is indispensable for reliable analysis of VOC breath biomarkers. Time resolution of direct mass spectrometers often is not sufficient to reliably resolve the phases of a breathing cycle. To realise fast on-line breath monitoring by means of direct MS utilising low-fragmentation soft ionisation, a data processing algorithm was developed to identify inspiratory and alveolar phases from MS data without any additional equipment. To test the algorithm selected breath biomarkers (acetone, isoprene, acetaldehyde and hexanal) were determined by means of quadrupole proton transfer reaction mass spectrometry (PTR-MS) in seven healthy volunteers during exercise on a stationary bicycle. The results were compared to an off-line reference method consisting of controlled alveolar breath sampling in Tedlar(R) bags, preconcentration by solid-phase micro extraction (SPME), separation and identification by GC-MS. Based on the data processing method, quantitative attribution of biomarkers to inspiratory, alveolar and mixed expiratory phases was possible at any time during the experiment, even under respiratory rates up to 60/min. Alveolar concentrations of the breath markers, measured by PTR-MS ranged from 130 to 2,600 ppb (acetone), 10 to 540 ppb (isoprene), 2 to 31 ppb (acetaldehyde), whereas the concentrations of hexanal were always below the limit of detection (LOD) of 3 ppb. There was good correlation between on-line PTR-MS and SPME-GC-MS measurements during phases with stable physiological parameters but results diverged during rapid changes of heart rate and minute ventilation. This clearly demonstrates the benefits of breath-resolved MS for fast on-line monitoring of exhaled VOCs.
2009
[Bajtarevic2009] Bajtarevic, A., C. Ager, M. Pienz, M. Klieber, K. Schwarz, M. Ligor, T. Ligor, W. Filipiak, H. Denz, M. Fiegl, et al., "Noninvasive detection of lung cancer by analysis of exhaled breath.", BMC Cancer, vol. 9: Department of Operative Medicine, Innsbruck Medical University, A-6020 Innsbruck, Austria. amel.bajtarevic@i-med.ac.at, pp. 348, 2009.
Link: http://dx.doi.org/10.1186/1471-2407-9-348
Abstract
{Lung cancer is one of the leading causes of death in Europe and the western world. At present, diagnosis of lung cancer very often happens late in the course of the disease since inexpensive, non-invasive and sufficiently sensitive and specific screening methods are not available. Even though the CT diagnostic methods are good, it must be assured that "screening benefit outweighs risk, across all individuals screened, not only those with lung cancer". An early non-invasive diagnosis of lung cancer would improve prognosis and enlarge treatment options. Analysis of exhaled breath would be an ideal diagnostic method, since it is non-invasive and totally painless.Exhaled breath and inhaled room air samples were analyzed using proton transfer reaction mass spectrometry (PTR-MS) and solid phase microextraction with subsequent gas chromatography mass spectrometry (SPME-GCMS). For the PTR-MS measurements, 220 lung cancer patients and 441 healthy volunteers were recruited. For the GCMS measurements, we collected samples from 65 lung cancer patients and 31 healthy volunteers. Lung cancer patients were in different disease stages and under treatment with different regimes. Mixed expiratory and indoor air samples were collected in Tedlar bags, and either analyzed directly by PTR-MS or transferred to glass vials and analyzed by gas chromatography mass spectrometry (GCMS). Only those measurements of compounds were considered, which showed at least a 15% higher concentration in exhaled breath than in indoor air. Compounds related to smoking behavior such as acetonitrile and benzene were not used to differentiate between lung cancer patients and healthy volunteers.Isoprene, acetone and methanol are compounds appearing in everybody's exhaled breath. These three main compounds of exhaled breath show slightly lower concentrations in lung cancer patients as compared to healthy volunteers (p < 0.01 for isoprene and acetone

Featured Articles

Download Contributions to the International Conference on Proton Transfer Reaction Mass Spectrometry and Its Applications:

 

Selected PTR-MS related Reviews

F. Biasioli, C. Yeretzian, F. Gasperi, T. D. Märk: PTR-MS monitoring of VOCs and BVOCs in food science and technology, Trends in Analytical Chemistry 30 (7) (2011).
Link

J. de Gouw, C. Warneke, T. Karl, G. Eerdekens, C. van der Veen, R. Fall: Measurement of Volatile Organic Compounds in the Earth's Atmosphere using Proton-Transfer-Reaction Mass Spectrometry. Mass Spectrometry Reviews, 26 (2007), 223-257.
Link

W. Lindinger, A. Hansel, A. Jordan: Proton-transfer-reaction mass spectrometry (PTR–MS): on-line monitoring of volatile organic compounds at pptv levels, Chem. Soc. Rev. 27 (1998), 347-375.
Link

 

Lists with PTR-MS relevant publications of the University of Innsbruck can be found here: Atmospheric and indoor air chemistry, IMR, Environmental Physics and Nano-Bio-Physics

 

Download the latest version of the IONICON publication database as BibTeX.