Callback Service

Undefined

The world's leading PTR-MS company

Providing ultra-sensitive solutions for real-time trace gas analysis since 1998

Navigation

You are here

Scientific Articles - PTR-MS Bibliography

Welcome to the new IONICON scientific articles database!

Publications

Found 4 results
[ Title(Desc)] Year
Filters: Author is Matteo Lanza  [Clear All Filters]
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z 
H
[1467] W. Acton, J., M. Lanza, B. Agarwal, S. Jürschik, P. Sulzer, K. Breiev, A. Jordan, E. Hartungen, G. Hanel, L. Märk, et al., "Headspace analysis of new psychoactive substances using a Selective Reagent Ionisation-Time of Flight-Mass Spectrometer", International Journal of Mass Spectrometry, pp. -, 2013.
Link: http://www.sciencedirect.com/science/article/pii/S1387380613004454
Abstract
<p>The rapid expansion in the number and use of new psychoactive substances presents a significant analytical challenge because highly sensitive instrumentation capable of detecting a broad range of chemical compounds in real-time with a low rate of false positives is required. A Selective Reagent Ionisation-Time of Flight-Mass Spectrometry (SRI-ToF-MS) instrument is capable of meeting all of these requirements. With its high mass resolution (up to m/Δm of 8000), the application of variations in reduced electric field strength (E/N) and use of different reagent ions, the ambiguity of a nominal (monoisotopic) m/z is reduced and hence the identification of chemicals in a complex chemical environment with a high level of confidence is enabled. In this study we report the use of a SRI-ToF-MS instrument to investigate the reactions of H3O+, O2+, NO+ and Kr+ with 10 readily available (at the time of purchase) new psychoactive substances, namely 4-fluoroamphetamine, methiopropamine, ethcathinone, 4-methylethcathinone, N-ethylbuphedrone, ethylphenidate, 5-MeO-DALT, dimethocaine, 5-(2-aminopropyl)benzofuran and nitracaine. In particular, the dependence of product ion branching ratios on the reduced electric field strength for all reagent ions was investigated and is reported here. The results reported represent a significant amount of new data which will be of use for the development of drug detection techniques suitable for real world scenarios.</p>
P
[1533] Sulzer, P., E. Hartungen, G. Hanel, S. Feil, K. Winkler, P. Mutschlechner, S. Haidacher, R. Schottkowsky, D. Gunsch, H. Seehauser, et al., "A Proton Transfer Reaction-Quadrupole interface Time-Of-Flight Mass Spectrometer (PTR-QiTOF): High speed due to extreme sensitivity", International Journal of Mass Spectrometry, vol. 368, pp. 1-5, 2014.
Link: http://www.sciencedirect.com/science/article/pii/S1387380614001584
Abstract
<p>Here we introduce a new prototype of a Proton Transfer Reaction-Time-Of-Flight Mass Spectrometry (PTR-TOFMS) instrument. In contrast to commercially available PTR-TOFMS devices so far, which utilize a transfer lens system, the novel prototype is equipped with a quadrupole ion guide for the highly effective transfer of ions from the drift tube to the mass spectrometer; hence we call it PTR-QiTOF, whereas &ldquo;Qi&rdquo; stands for &ldquo;Quadrupole interface&rdquo;. This new interface greatly improves the TOF mass resolution because of favorable injection conditions. Depending on whether we optimize the PTR-QiTOF to maximum sensitivity or maximum mass resolution, we get about 6900 and 10,400 m/m mass resolution, respectively, already at m/z 149 (increasing with ascending masses). Furthermore, we increase the pressure in the drift tube from typically 2.2 mbar to 3.8 mbar and the drift tube voltage from 600V to 1000 V. We directly compare the sensitivities of a commercial state-of-the-art PTR-TOFMS instrument to this &ldquo;high pressure&rdquo; PTR-QiTOF prototype and find that these modifications lead to a gain on average by a factor of 25 in terms of sensitivity with a maximum of about 4700 cps/ppbv for dichlorobenzene atm/z 147 for the PTR-QiTOF. This is (to our knowledge) the highest sensitivity ever reported for a PTR-MS instrument, regardless of the employed mass spectrometer. The increased sensitivity also has a very positive effect on the detection limit, which lies now at about 20 pptv with 100ms and 750 ppqv after 1 min integration time.Weprovide data on the linearity of the instrumental response over a concentration range of five orders of magnitude and evaluate the prototype&rsquo;s performance in a real-life test by analyzing the dynamic headspace of a minute amount of trinitrotoluene using only 2 s integration time.</p>
S
[1817] Materić, D., M. Lanza, P. Sulzer, J. Herbig, D. Bruhn, V. Gauci, N. Mason, and C. Turner, "Selective reagent ion-time of flight-mass spectrometry study of six common monoterpenes", International Journal of Mass Spectrometry, jun, 2017.
Link: http://www.sciencedirect.com/science/article/pii/S1387380617303044?via%3Dihub
Abstract
<p>One of the most common volatile organic compounds (VOCs) group is monoterpenes. Monoterpenes share the molecular formula C10H16, they are usually cyclic and have a pleasant smell. The most common monoterpenes are limonene (present in citrus fruits) and α-pinene (present in conifers&rsquo; resin). Different monoterpenes have different chemical, biological and ecological properties thus it is experimentally very important to be able to differentiate between them in real time. Real time instruments such as Proton Transfer Reaction-Time of Flight-Mass Spectrometry (PTR-ToF-MS), offer a real time solution for monoterpene measurement but at the cost of selectivity resulting in all monoterpenes being seen at the same m/z. In this work we used Selective Reagent Ion-Time of Flight-Mass Spectrometry (SRI/PTR-ToF-MS) in order to explore the differences in ion branching when different ionizations (H3O+, NO+ and O2+) and different drift tube reduced field energies (E/N) were used. We report a comprehensive ion library with many unique features, characteristic for individual monoterpenes.</p>
T
[1464] Edtbauer, A., E. Hartungen, A. Jordan, G. Hanel, J. Herbig, S. Jürschik, M. Lanza, K. Breiev, L. Märk, and P. Sulzer, "Theory and practical examples of the quantification of CH4, CO, O2, and \{CO2\} with an advanced proton-transfer-reaction/selective-reagent-ionization instrument (PTR/SRI-MS)", International Journal of Mass Spectrometry, pp. -, 2013.
Link: http://www.sciencedirect.com/science/article/pii/S1387380613004235
Abstract
<p>Abstract Following up the first introduction of an advanced proton-transfer-reaction mass spectrometry (PTR-MS) instrument in 2012, which is capable of utilizing H3O+, NO+, O2+, and Kr+, respectively, for chemical ionization and subsequent detection of a broad variety of compound classes, here we present calculations of the best suitable mixing ratios between the sample and buffer gas in Kr+ mode, as well as two possible applications of such an instrument in indoor air analysis and engine exhaust studies. Due to secondary reactions in the drift tube the admixing of a buffer gas with a higher recombination energy than Kr+ is inevitable. The calculations show that though a dilution ratio of 1:40 (sample : buffer gas) results in the highest sensitivity, for accurate substance quantification a dilution ratio of at least 1:500 is necessary. By applying this theoretical knowledge to two practical examples, we find that the quantification of CH4, CO, O2, and CO2, respectively, is well within the range of the expected concentrations. We conclude that such an instrument can be of utmost benefit for researchers working for example in environmental research, because in H3O+ mode volatile organic compounds can be quantified with very high sensitivity and low detection limits and by means of switching the reagent ions to Kr+ additional instrumentation for quantification of (inorganic) pollutants becomes virtually obsolete.</p>

Featured Articles

Download Contributions to the International Conference on Proton Transfer Reaction Mass Spectrometry and Its Applications:

 

Selected PTR-MS related Reviews

F. Biasioli, C. Yeretzian, F. Gasperi, T. D. Märk: PTR-MS monitoring of VOCs and BVOCs in food science and technology, Trends in Analytical Chemistry 30 (7) (2011).
Link

J. de Gouw, C. Warneke, T. Karl, G. Eerdekens, C. van der Veen, R. Fall: Measurement of Volatile Organic Compounds in the Earth's Atmosphere using Proton-Transfer-Reaction Mass Spectrometry. Mass Spectrometry Reviews, 26 (2007), 223-257.
Link

W. Lindinger, A. Hansel, A. Jordan: Proton-transfer-reaction mass spectrometry (PTR–MS): on-line monitoring of volatile organic compounds at pptv levels, Chem. Soc. Rev. 27 (1998), 347-375.
Link

 

Lists with PTR-MS relevant publications of the University of Innsbruck can be found here: Atmospheric and indoor air chemistry, IMR, Environmental Physics and Nano-Bio-Physics

 

Download the latest version of the IONICON publication database as BibTeX.