Callback Service

Undefined

The world's leading PTR-MS company

Providing ultra-sensitive solutions for real-time trace gas analysis since 1998

Navigation

You are here

Scientific Articles - PTR-MS Bibliography

Welcome to the new IONICON scientific articles database!

Publications

Found 7 results
Title [ Year(Asc)]
Filters: Author is Prazeller, Peter  [Clear All Filters]
2007
[Velasco2007] Velasco, E., B. Lamb, H. Westberg, E. Allwine, G. Sosa, JL. Arriaga-Colina, BT. Jobson, L. M Alexander, P. Prazeller, W. B. Knighton, et al., "Distribution, magnitudes, reactivities, ratios and diurnal patterns of volatile organic compounds in the Valley of Mexico during the MCMA 2002 & 2003 field campaigns", Atmospheric Chemistry and Physics, vol. 7, no. 2: Copernicus GmbH, pp. 329–353, 2007.
Link: http://www.atmos-chem-phys.net/7/329/2007/acp-7-329-2007.html
Abstract
A wide array of volatile organic compound (VOC) measurements was conducted in the Valley of Mexico during the MCMA-2002 and 2003 field campaigns. Study sites included locations in the urban core, in a heavily industrial area and at boundary sites in rural landscapes. In addition, a novel mobile-laboratory-based conditional sampling method was used to collect samples dominated by fresh on-road vehicle exhaust to identify those VOCs whose ambient concentrations were primarily due to vehicle emissions. Four distinct analytical techniques were used: whole air canister samples with Gas Chromatography/Flame Ionization Detection (GC-FID), on-line chemical ionization using a Proton Transfer Reaction Mass Spectrometer (PTR-MS), continuous real-time detection of olefins using a Fast Olefin Sensor (FOS), and long path measurements using UV Differential Optical Absorption Spectrometers (DOAS). The simultaneous use of these techniques provided a wide range of individual VOC measurements with different spatial and temporal scales. The VOC data were analyzed to understand concentration and spatial distributions, diurnal patterns, origin and reactivity in the atmosphere of Mexico City. The VOC burden (in ppbC) was dominated by alkanes (60%), followed by aromatics (15%) and olefins (5%). The remaining 20% was a mix of alkynes, halogenated hydrocarbons, oxygenated species (esters, ethers, etc.) and other unidentified VOCs. However, in terms of ozone production, olefins were the most relevant hydrocarbons. Elevated levels of toxic hydrocarbons, such as 1,3-butadiene, benzene, toluene and xylenes, were also observed. Results from these various analytical techniques showed that vehicle exhaust is the main source of VOCs in Mexico City and that diurnal patterns depend on vehicular traffic in addition to meteorological processes. Finally, examination of the VOC data in terms of lumped modeling VOC classes and its comparison to the VOC lumped emissions reported in other photochemical air quality modeling studies suggests that some alkanes are underestimated in the emissions inventory, while some olefins and aromatics are overestimated.
2004
[Boscaini2004a] Boscaini, E., M. L. Alexander, P. Prazeller, and T. D. Märk, "Investigation of fundamental physical properties of a polydimethylsiloxane (PDMS) membrane using a proton transfer reaction mass spectrometer (PTRMS)", International Journal of Mass Spectrometry, vol. 239, no. 2: Elsevier, pp. 179–186, 2004.
Link: http://www.sciencedirect.com/science/article/pii/S1387380604003586
Abstract
A membrane introduction proton transfer reaction mass spectrometer (MI-PTRMS) has been employed for the characterisation of a polydimethylsiloxane (PDMS) membrane. For this purpose the diffusion and partition coefficients (which serve as a measure for solubility) have been determined experimentally for different classes of chemical compounds both non-polar and polar species, i.e., aromatics, alcohols, and ketones. It turned out that not only polar compounds exhibit strong interaction with a hydrophobic membrane such as the PDMS, but also non-polar compounds as trimethylbenzene or propylbenzene show strong interaction with a PDMS membrane. Stronger analyte–membrane interaction leads to a slower diffusion coefficient and larger partition coefficient. The effect of the temperature on the diffusion coefficient and partition coefficient has also been investigated, i.e., at higher temperature diffusion becomes faster and solubility lower. Permeability can be calculated from diffusion and partition coefficients and the activation energy has been derived from corresponding Arrhenius plots. The MI-PTRMS system shows detection limits in the order of tens of pptv and its response is linear for more than four orders of magnitude.
[Boscaini2004b] Boscaini, E., M. L. Alexander, P. Prazeller, and T. D. Märk, "Membrane inlet proton transfer reaction mass spectrometry (MI-PTRMS) for direct measurements of VOCs in water", International Journal of Mass Spectrometry, vol. 239, no. 2: Elsevier, pp. 171–177, 2004.
Link: http://www.sciencedirect.com/science/article/pii/S1387380604003896
Abstract
The use of a membrane inlet proton transfer reaction mass spectrometry (MI-PTRMS) system was investigated for the quantitative analysis of VOCs directly from water. Compounds playing an important role in environmental, biological and health issues such as methanol, acetonitrile, acetone, dimethylsulfide (DMS), isoprene, benzene, and toluene have been analyzed both in fresh and salty water. The system shows very good sensitivity, reproducibility, and a linear response of up to five orders of magnitude. The detection limit for DMS is about 100 ppt and for methanol is about 10 ppb both in fresh and salty water. The response time of the various compounds across the membrane is on the order of a few minutes. This fast response and the fact that the PTRMS can perform absolute measurements without the necessity of calibration make the system suitable for on-line and -site measurements of VOCs directly from water.
2003
[Prazeller2003] Prazeller, P., P. T. Palmer, E. Boscaini, T. Jobson, and M. Alexander, "Proton transfer reaction ion trap mass spectrometer", Rapid communications in mass spectrometry, vol. 17, no. 14: Wiley Online Library, pp. 1593–1599, 2003.
Link: http://onlinelibrary.wiley.com/doi/10.1002/rcm.1088/full
Abstract
Proton transfer reaction mass spectrometry is a relatively new field that has attracted a great deal of interest in the last few years. This technique uses H3O+ as a chemical ionization (CI) reagent to measure volatile organic compounds (VOCs) in the parts per billion by volume (ppbv) to parts per trillion by volume (pptv) range. Mass spectra acquired with a proton transfer reaction mass spectrometer (PTR-MS) are simple because proton transfer chemical ionization is ‘soft’ and results in little or no fragmentation. Unfortunately, peak identification can still be difficult due to isobaric interferences. A possible solution to this problem is to couple the PTR drift tube to an ion trap mass spectrometer (ITMS). The use of an ITMS is appealing because of its ability to perform MS/MS and possibly distinguish between isomers and other isobars. Additionally, the ITMS duty cycle is much higher than that of a linear quadrupole so faster data acquisition rates are possible that will allow for detection of multiple compounds. Here we present the first results from a proton transfer reaction ion trap mass spectrometer (PTR-ITMS). The aim of this study was to investigate ion injection and storage efficiency of a simple prototype instrument in order to estimate possible detection limits of a second-generation instrument. Using this prototype a detection limit of 100 ppbv was demonstrated. Modifications are suggested that will enable further reduction in detection limits to the low-ppbv to high-pptv range. Furthermore, the applicability of MS/MS in differentiating between isobaric species was determined. MS/MS spectra of the isobaric compounds methyl vinyl ketone (MVK) and methacrolein (MACR) are presented and show fragments of different mass making differentiation possible, even when a mixture of both species is present in the same sample. However, MS/MS spectra of acetone and propanal produce fragments with the same molecular masses but with different intensity ratios. This allows quantitative distinction only if one species is predominant. Fragmentation mechanisms are proposed to explain the results.
2001
[Karl2001] Karl, T., P. Prazeller, D. Mayr, A. Jordan, J. Rieder, R. Fall, and W. Lindinger, "Human breath isoprene and its relation to blood cholesterol levels: new measurements and modeling", Journal of Applied Physiology, vol. 91, no. 2, pp. 762-770, 2001.
Link: http://jap.physiology.org/content/91/2/762.abstract
Abstract
Numerous publications have described measurements of breath isoprene in humans, and there has been a hope that breath isoprene analyses could be a noninvasive diagnostic tool to assess blood cholesterol levels or cholesterol synthesis rate. However, significant analytic problems in breath isoprene analysis and variability in isoprene levels with age, exercise, diet, etc., have limited the usefulness of these measurements. Here, we have applied proton transfer reaction-mass spectrometry to this problem, allowing on-line detection of breath isoprene. We show that breath isoprene concentration increases within a few seconds after exercise is started as a result of a rapid increase in heart rate and then reaches a lower steady state when breath rate stabilizes. Additional experiments demonstrated that increases in heart rate associated with standing after reclining or sleeping are associated with increased breath isoprene concentrations. An isoprene gas-exchange model was developed and shows excellent fit to breath isoprene levels measured during exercise. In a preliminary experiment, we demonstrated that atorvastatin therapy leads to a decrease in serum cholesterol and low-density-lipoprotein levels and a parallel decrease in breath isoprene levels. This work suggests that there is constant endogenous production of isoprene during the day and night and reaffirms the possibility that breath isoprene can be a noninvasive marker of cholesterologenesis if care is taken to measure breath isoprene under standard conditions at constant heart rate.
1999
[Prazeller1999] Prazeller, P., K. Thomas, A. Jordan Arm Hansel, and W. Lindinger, "Acetonitril als Biomarker zur Quantifizierung des Passivrauchens", Ber. nat-med. Verein Innsbruck, vol. 86: Ber. nat-.med. Verein Innsbruck, pp. 13-19, 1999.
Link: http://www.landesmuseum.at/pdf_frei_remote/BERI_86_0013-0019.pdf
1997
[Jordan1997] Jordan, A., A. Hansel, C. WARNECKE, R. Holzinger, P. Prazeller, W. Vogel, and W. Lindinger, ""On-line" Spurengasanalyse im ppt-Bereich und ihre Anwendungen auf Gebieten der Medizin, Lebensmittelforschung und Luftqualität", , no. 84: Ber. nat-.med. Verein Innsbruck, pp. 7-17, 1997.
Link: http://www.landesmuseum.at/pdf_frei_remote/BERI_84_0007-0017.pdf

Featured Articles

Download Contributions to the International Conference on Proton Transfer Reaction Mass Spectrometry and Its Applications:

 

Selected PTR-MS related Reviews

F. Biasioli, C. Yeretzian, F. Gasperi, T. D. Märk: PTR-MS monitoring of VOCs and BVOCs in food science and technology, Trends in Analytical Chemistry 30 (7) (2011).
Link

J. de Gouw, C. Warneke, T. Karl, G. Eerdekens, C. van der Veen, R. Fall: Measurement of Volatile Organic Compounds in the Earth's Atmosphere using Proton-Transfer-Reaction Mass Spectrometry. Mass Spectrometry Reviews, 26 (2007), 223-257.
Link

W. Lindinger, A. Hansel, A. Jordan: Proton-transfer-reaction mass spectrometry (PTR–MS): on-line monitoring of volatile organic compounds at pptv levels, Chem. Soc. Rev. 27 (1998), 347-375.
Link

 

Lists with PTR-MS relevant publications of the University of Innsbruck can be found here: Atmospheric and indoor air chemistry, IMR, Environmental Physics and Nano-Bio-Physics

 

Download the latest version of the IONICON publication database as BibTeX.