Performance data, publications and application examples of IONICON PTR-TOF-MS instruments

Here we would like to share the performance of our PTR-TOFMS series with you. The IONICON PTR-TOF 8000 and the PTR-TOF 2000 are different but both have their advantages. Below you will find a comparison of typical resolution and sensitivity of both instruments.

Performance data from IONICON PTR-TOF 8000 instruments:

Low Detection Limits

Single digit-pptv level LoD also with a time of flight based PTR-MS (click to enlarge graphs):

High Resolution

Graphs showing measured mass resolution of two PTR-TOF 8000 systems.
A maximum resolution of 7000-8000 can be seen.

click to enlarge click to enlarge
Separated peaks from Methylketene and Butene and their resolution Benzene peak with a mass resolution > 7000
click to enlarge click to enlarge

Performance data from IONICON PTR-TOF 2000 instruments:

High Sensitivity

 

Comparison of PTR-TOF 2000 and PTR-TOF 8000 ion yields and sensitivities. Typical mass resolution of a PTR-TOF 2000
click to enlarge click to enlarge
 

Advantages of the high-resolution PTR-TOF 8000

Comparing Furan and Isoprene one can see the importance of very high resolution, allowing to clearly separate both peaks.
click to enlarge  
Furan and Isoprene can easily be separated and identified using a PTR-TOF 8000 system. A time of flight with a lower resolution will sum up both substances in one peak.



Related downloads:

IONICON PTR-TOF-MS technology and product presentation (1.0 MB .pdf)
IONICON PTR-TOF 8000 product factsheet (0.2 MB .pdf)
IONICON PTR-TOF 2000 product factsheet (0.2 MB .pdf)

Related articles in press:

M. Mueller, M. Graus, A. Wisthaler, A. Hansel, A. Metzger, J. Dommen, U. Baltensperger: Analysis of high mass resolution PTR-TOF mass spectra from 1,3,5-trimethylbenzene (TMB) environmental chamber experiments, Atmos. Chem. Phys., 12 (2012), 829–843. Link

L. Cappellina, F. Biasioli, A. Fabris, E. Schuhfried, C. Soukoulis, T. D. Märk, F. Gasperi: Improved mass accuracy in PTR-TOF-MS: Another step towards better compound identification in PTR-MS, International Journal of Mass Spectrometry 290 (2010), 60–63. Link

M. Müller, M. Graus, T. M. Ruuskanen, R. Schnitzhofer, I. Bamberger, L. Kaser, T. Titzmann, L. Hörtnagl, G. Wohlfahrt, T. Karl, A. Hansel: First eddy covariance flux measurements by PTR-TOF, Atmos. Meas. Tech. 3 (2010), 387–395. Link

C.A. Mayhew, P. Sulzer, F. Petersson, S. Haidacher, A. Jordan, L. Märk, P. Watts, T.D. Märk: Applications of proton transfer reaction time-of-flight mass spectrometry for the sensitive and rapid real-time detection of solid high explosives, International Journal of Mass Spectrometry (2009). Link

A. Jordan, S. Haidacher, G. Hanel, E. Hartungen, L. Märk, H. Seehauser, R. Schottkowsky, P. Sulzer, T.D. Märk: A high resolution and high sensitivity time-of-flight proton-transfer-reaction mass spectrometer (PTR-TOF-MS), International Journal of Mass Spectrometry (2008). Link

Click here for more articles.